gemino
54
CONFIGURATION USING THE KEYPAD
The device can be controlled and configured using the
ergo
keypad connected
to the KS-BUS terminals or using the rapid connection cable.
gemino
has two
menus:
Setting menu
You can set all the parameters described in the previous chapter.
To gain access to this menu, enter the factory code 123456.
The peripherals connected to
gemino
can be configured using the
ergo
keypad.
Scroll the menu up to the voice “Peripherals”. Press the “Enter” key. 5 parameters
are available:
Assign:
In this menu the peripherals connected to
gemino
but still unset are shown.
Each peripherals is identified with a serial number. A new program, or a program
set with the software, can be associated to each peripherals.
Program:
This menu allows to modify the configuration of the device terminals
connected to
gemino
.
Eject:
This menu allows to delete the peripherals that may be disconnected from
gemino
. The terminals configuration is not deleted during this operation and it can
be reused with a different device.
Delete:
This menu allows to delete the peripherals that must be disconnected
from
gemino
. The terminals configuration is deleted too.
Default:
Assign the zones to the devices connected with
gemino
. I.E.: If a
auxi
or an
ergo
are connected to
gemino
, the 1 to 5 zones are assigned to M1 to M5 terminals
of
auxi
, the 6 and 7 zones to M1 and M2 terminals of the
ergo
. During the DEFAULT
operation, pre-existent programs are deleted.
Management menu
You can only configure the index book and check the status of the device.
To gain access to this menu, enter the factory code 147258.