IP EVENTS
Synchronyze time with receiver:
allows you to use the time of receiver to
synchronyze the time on device
Receiver 1 • 2
(main - backup)
Description:
Name associated with receiver.
NOTE: The following parameters are assigned by Alarm Monitoring Station
ID Receiver:
SIA IP DC-09 identifier of receiver, 6 hexadecimal digits max.
ID Trasport layer:
SIA IP DC-09 identifier of the device used with the current
receiver, 12 hexadecimal digits max.
IP Address:
IP address of receiver.
Port:
Remote Port on which the receiver is listening.
Protocol:
Application protocol, used to format the data field of the SIAIP DC09
transport protocol (Contact-ID, SiaLevel3, ...).
ID Application layer:
Identifier of the device application protocol (Contact ID ,
Sialevel3) used with the current receiver.
Options
Automatic BackUp:
Communication to this receiver, in case of failure, repeats to
the backup receiver
BackUp Priority:
The communication has sent to the backup receiver FIRST, and
then, in case of failure, repeated the main receiver.
Transmits over TCP:
Sets the use of TCP protocol instead of UDP to send
signalisations.
Use timestamp:
If selected, this option sets the presence of date and hour
informations on data packet
Max Attemps
Max replies DUH:
number of responses received before considering the package
submitted does not syntactically correct
Max replies NAK:
number of responses received before considering the package
submitted does not correct
Max no replies:
Number of timeouts that occurred before to close the
communication due the timeout
BackUp
BackUp Period:
Time, in seconds, that you send notifications on backup receiver
once the main receiver is off
Max communication attemps:
Number of failed transmissions before to
considerate the main receiver as off
CONFIGURATION PARAMETERS