Hydro module
C1 Hydro module electrical supply cable.
2
Outdoor unit air - water
C2 External unit air - water (electrical supply cable).
A Cooling connection - gas
pipe
C3 Modbus cable for communication between internal and
outdoor unit
B Cooling connection - liquid
pipe
3.6.3 CABLE INSTALLATION
CAUTION
Lay the cables of the heating system elements as shown on the picture below. The
cables must be of sufficient length to allow the electrical cabinet to be opened
during service.
Picture 23: Laying the cables in the electrical cabinet.
3.6.4 POWER CONNECTION
DANGER
Connecting the device to the power source can only be performed by a qualified
installer in a
voltage-free
state.
CAUTION
The supply and communication cables have to be laid into the device and electrical
cabinet through separate cable glands and cord anchorage, which are installed
before the cable terminals. This way we ensure the cable is relieved from strain and
the electrical cabinet is protected from water penetration.
CAUTION
Wrong dimensioning of the power cable or too weak terminal fuses of the device
could lead to an overload of the safety elements on the power grid of the
building which could lead to overheating of the electrical installation. Follow the
requirements listed in this manual.