40
CAUTION
In case of connecting the multi-wire flexible cable to the connecting terminal, it always
has to have an end sleeve end sleeve at the end.
1
End sleeve
2
Multi-wire flexible conductor
3
Massive single-wire cable
To connect to connecting terminal of the device, use cables with necking dies or
massive single-wire cables.
The dimensions of the power cables are listed in the chapter under technical
information 4.2.
3.6.4.1 One-phase connection ~230 V / 50 Hz
–
16 A
NOTE
In one-phase connection ~230 V / 50 Hz
– 16 A the power of the electric heater is
2 kW.
Connect the cable of an appropriate cross-section
to the terminal , N and L1.
3.6.4.2 One-phase connection ~230 V / 50 Hz
–
20 A
NOTE
In one-phase connection ~230 V / 50 Hz
– 16 A the power of the electric heater is
4 kW.
Connect the cable of an appropriate cross-section
to the terminal , N and L1. Make a bridge
between terminal L1 and L2.
Summary of Contents for HM-130 S1
Page 10: ...10 2 INSTRUCTIONS FOR THE END USER ...
Page 13: ...13 ...
Page 14: ...14 3 INSTRUCTIONS FOR THE INSTALLER ...
Page 49: ...49 4 TECHNICAL CHARACTERISTICS ...
Page 53: ...53 4 1 5 ELECTRICAL SCHEME Picture 27 Electrical scheme of the device ...
Page 58: ...58 ...
Page 59: ...59 ...