Kramer Electronics Ltd.
VP-554X
– Defining VP-554X Presentation Switcher/Scaler
6
Figure 2: VP-554X Presentation Switcher/Scaler Rear Panel
#
Feature
Function
VIDEO OUTPUT
Connectors
(OUT 1 to OUT 4)
IR (Rx, Tx) left 2-pins on
a 5-pin Terminal Block
Connector
Connect to the IR connector of an HDBT input (Tx
to Rx and Rx to Tx), to tunnel IR data between an
HDBT receiver on an output and an HDBT
transmitter on an input.
RS-232 (G, Rx, Tx) right
3-pins on a 5-pin
Terminal Block
Connector
Tunnel RS-232 data between the HDBT port and
the HDBT receiver: Connect to serially control a
device connected to the HDBT receiver; or to
serially control a local device using a controller
connected to the HDBT receiver.
HDBT RJ-45 Connector
Connect to an HDBT receiver.
When connecting a device to the HDBT port,
in some cases, RS-232 data may not pass
from the connected device to the HDBT port.
To fix and configure this, go to the Setting
tab in the Data routing page and change
Data Channel to 4 (see
Routing Parameters on page
HDMI
Connect to an HDMI acceptor.
HDMI IN Connectors
Connect to an HDMI source (IN 1 to IN 6).
PC IN 15-pin HD Connector
Connect to a VGA computer graphics source.
VIDEO INPUT
Connectors
(HDBT IN1 to
HDBT IN4)
HDBT IN RJ-45
Connector
Connect to an HDBT transmitter (IN 1 to IN 4).
When connecting a device to the HDBT port,
in some cases, RS-232 data may not pass
from the connected device to the HDBT port.
To fix and configure this, go to the Setting
tab in the Data routing page and change
Data Channel to 4 (see
Routing Parameters on page
IR (Rx, Tx) left 2-pins on
a 5-pin Terminal Block
Connectors
Connect to the IR connector of an HDBT output (Tx
to Rx and Rx to Tx), to tunnel IR data between an
HDBT transmitter on the input and HDBT receiver
on an output.
RS-232 (G, Rx, Tx) right
3-pins on a 5-pin
Terminal Block
Connectors
Connect to a serial controller or RS-232 controlled
device for RS-232 link extension via the HDBT input
(for HDBT IN 1 to IN 4).
EXT. CONTROL (G, Rx, Tx) 3-pin Terminal
Block Connector
Connect to an external RS-232 device to be
controlled (for example, a projector).
CONTROL (G, Rx, Tx) 3-pin Terminal Block
Connector
Connect to a PC or remote controller to control
VP-554X
via Protocol 3000 commands.
The port includes echoing when changes are made
to the machine.
DATA RJ-45 Connector
Connect to a PC or other controller through
computer networking. (Data 1 and Data 2).
15
16
17
18
19
20
21