![Konica Minolta SONIMAGE HS2 Operation Manual Download Page 230](http://html1.mh-extra.com/html/konica-minolta/sonimage-hs2/sonimage-hs2_operation-manual_1994056230.webp)
230
6 .4 Transferring Image Data
Item
Functions
[Clip File Format]
Selects an output format of a clip file.
[Type 1(* .avi)]
• Outputs in * .avi format . Suitable for playback on monitors for medical use that have applied
GSDF (DICOM curve) .
[Type 2(* .mp4)]
• Outputs in * .mp4 format . Perfect for playback on typical computer monitors and it is the small-
est file size.
[Type 3(* .avi)]
• Outputs in * .avi format . Suitable for playback on typical computer monitors .
Select this if playback cannot be done using the Type 2 format .
[DICOM(DCM)]*
• This is set if the [Export Image] is in [DICOM Format] .
Detailed formats to output depend on the [Contrast Compensation] of the DICOM media stor-
age . For details, refer to "DICOM Screen" of the "Operation Manual: Applications" .
[Clip File Frame Rate]
Selects and changes the frame rate of a clip file.
[Hide patient data]
Sets whether to mask the patient information of the image and output .
• Mark the check box to mask and output the patient information .
• If, with the check box marked, an uneditable image is included in the output, a message appears,
confirming that there is an image to be output without masking the patient information. Then you
are prompted to choose between continuing the operation and canceling it .
*
: Selectable only when the optional "DICOM Storage License" has been installed .
5
Press the [Export Image] button on the [Export Image] screen to execute .
• Images are output to an external storage medium .
6
Upon completion of the output, touch the SD memory card icon in the status indicator area .
• A message appears in the pop-up window, confirming that the external storage medium can be safely re-
moved .
7
Select the Remove icon
for SD memory card desired to be removed and then remove
the SD memory card .
• The SD memory card icon is hidden .
HINT
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
• In the [Other] tab of the menu pop-up window, you can use
to write image data .
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Summary of Contents for SONIMAGE HS2
Page 1: ...EN 01...
Page 2: ......
Page 6: ...6...
Page 7: ...7 Introduction...
Page 41: ...41 For all product inquiries contact your service representative Support...
Page 42: ...42...
Page 43: ...43 Chapter 1 Product Overview...
Page 68: ...68...
Page 69: ...69 Chapter 2 Before Examination...
Page 84: ...84...
Page 85: ...85 Chapter 3 Starting Examination...
Page 122: ...122...
Page 123: ...123 Chapter 4 Diagnosis Mode...
Page 181: ...181 Chapter 5 Common Function in Ultrasound Images...
Page 219: ...219 Chapter 6 Reviewing Printing and Transferring Images...
Page 232: ...232...
Page 233: ...233 Chapter 7 Maintenance Inspection...
Page 243: ...243 Chapter 8 Transducer and Biopsy...
Page 270: ...270...
Page 271: ...271 Chapter 9 MI TI...
Page 283: ...283 Chapter 10 Acoustic Output...
Page 286: ...286...
Page 287: ...287 Chapter 11 Others...
Page 305: ...305...
Page 306: ...306...
Page 307: ......