Cable
Type
From/To
Minimum requirements
DC power cable
From Power Supply Unit to
Wide Band Transceiver (WBT)
C16*
The DC power cable from the WBT power supply to the transceiver is provided with the
power supply. The Wide Band Transceiver (WBT) can be powered by a large capacity
battery. The battery must be placed close to the Wide Band Transceiver (WBT) to
minimize power loss in the cable.
C17*
AC power cable
From Power Supply Unit to AC
power outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
Synchronization
cable
From Wide Band Transceiver
(WBT)
Auxiliary
socket to
external synchronisation system.
4 x 0.5 mm²
C18
If you use more than one Wide Band Transceiver (WBT) in your EK80 system, all
synchronization input signals to the
Auxiliary
ports must be provided by the same
source.
C19
Not used
Transducer cable
From Wide Band Transceiver
(WBT) to transducer
C20**
The transducer cable is provided with the transducer.
C21*
AC power cable
From WBT Cabinet to AC power
outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C22-24
Not used
AC power cable
From Ethernet switch to AC
power outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C25*
The power cable on the Ethernet switch may comprise a separate power supply.
C26–29
Not used
EC150-3C cables
Cable
Type
From/To
Minimum requirements
Ethernet cable
From Power Supply Unit to
Processor Unit
CAT5-E STP (Shielded Twisted
Pair)
C8
It is very important that a high-quality Ethernet cable is used. You must use CAT-5E
STP (Shielded Twisted Pair) quality or better. If you use a cable with lower bandwidth
capacity you will reduce the EK80 performance.
C30*
AC power cable
From Power Supply Unit to
AC power outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
Synchronization
cable
From Power Supply Unit to
synchronization system
2 x 2 x 0.5 mm
2
C31
Synchronization is an optional feature. We strongly recommend that each signal cable
is equipped with galvanic isolation. Galvanic isolation reduces the risk of noise.
C32
Ground cable
From Power Supply Unit to
vessel ground
1 x 6 mm
2
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...