146
394149/D
RS-232 connection to your peripheral device work properly, you must always consult the
relevant instructions provided by the device manufacturer.
Pin configuration
Moxa CP114EL-I connectors / Adapter cable
Pin
RS-232
RS-422
RS-485 (4-wire)
RS-485 (2-wire)
1
DCD
TXD-(A)
TXD-(A)
2
RxD
TXD+(B)
TXD+(B)
3
TxD
RXD+(B)
RXD+(B)
Data-(B)
4
DTR
RXD-(A)
RXD-(A)
Data-(A)
5
Ground
Ground
Ground
Ground
6
DSR
7
RTS
8
CTS
9
Minimum cable requirements
•
Conductors
: 2 x 5 x 0.5 mm
2
•
Screen
: Overall braided
•
Voltage
: 60 V
•
Maximum outer diameter
: Defined by the plugs and/or the cable gland
If you wish to use RS-422 or RS-485 serial communication, use a cable with twisted
pairs. If you need to install a very long cable, increase the cross section.
Related topics
Cable drawings and specifications, page 136
About serial lines, page 164
Cable layout and interconnections, page 85
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...