394149/D
63
Coordinate system alternative origins
If necessary, other origin locations may be defined for specific products or purposes. One
example is the
Navigation Reference Point
that is frequently used. Whenever a vessel
is surveyed to establish accurate offset information, the surveyor may also establish an
alternative origin location. Whenever relevant, any such alternative locations must
be defined using offset values to the "official" origin established by the designer or
shipyard. A commonly used alternative origin is the physical location of the vessel’s
motion reference unit (MRU).
Defining the physical location of each sensor
By means of the vessel coordinate system, the physical location of every sensor can
be defined using three numerical values for X, Y and Z. These values must define the
vertical and horizontal distances from a single reference point; the origin. The physical
location of the motion reference unit (MRU) is often the most important sensor to define.
For many systems, the vessel heading is also a critical measurement.
Illustration:
In this example, a second
reference point has been
established. It is defined with
three positive offset values
for X, Y and Z. All values
are positive because the new
reference point is in front of
and below the origin, and on
the starboard side.
The accuracy of the three numerical values for X, Y and Z defines the accuracy of the
sensor data. If you require a high accuracy, for example for underwater positioning,
underwater mapping or scientific measurements, you must have each sensor positioned
using professional land surveying. For such use, a good alignment survey is critical for
high quality results. Surveys are normally done by qualified and trained surveyors using
proven survey equipment and methods.
Related topics
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...