248
394149/D
• The EK80 system is turned on and operates normally.
Neither tools nor instruments are required.
Context
The information imported to the EK80 from
various sensors can also be useful for other
systems on board your vessel. The EK80 allows
you to "re-export" this sensor information. When
activated, the selected sensor information is sent
out on the chosen communication port (serial or
LAN) on the Processor Unit.
The following sensor data can be exported:
• Navigation
• Motion sensor
Procedure
1
Connect the peripheral system to an
available communication port on your
Processor Unit.
This is described in the
Cable layout and interconnections
chapter. Observe the
applicable requirements related to cabling. Make sure that the total length of the
serial line cable does not exceed approximately 50 meters. If a longer cable is
required, you may need to use buffer amplifiers.
If the Processor Unit is not fitted with a suitable serial line connector, use a
USB-to-serial converter. Several types are commercially available. Note that most
USB-to-serial converters will introduce some latency. They may also introduce
be jitter in the communication. The amount of jitter depends on the quality of
the converter.
2
Open the
Operation
menu.
3
Select
Output
.
Observe that the
Output
dialog box opens. This dialog box contains a number of
pages selected from the menu on the left side.
4
On the left side of the dialog box, select
I/O Setup
.
5
Observe that the available serial and network interface ports on the Processor Unit
are listed.
6
Set up the relevant serial or Ethernet (LAN) communication parameters.
a
On the
I/O Setup
page, select the port you wish to set up.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...