98
394149/D
Related topics
Installing the EK80 cables, page 97
Cable layout and interconnections, page 85
Installing the EK80 topside cables
The topside/bridge cables include those used to connect the EK80 Processor Unit and the
display to each other, to AC mains power, and to external devices. One high capacity
Ethernet cable connects the Processor Unit to the Wide Band Transceiver (WBT).
Procedure
1
Connect the power cables.
a
Connect the power cable from the display to the AC power outlet. (C1)
b
Connect the power cable from the Processor Unit to the AC power outlet. (C2)
Standard commercial AC mains cables are used. Each cable is supplied with the
relevant unit. The typical cable length is between 1,5 and 2 meters. If this is too
short you must use an extension cable (not recommended), mount a new power
outlet within range, or make your own power cable with sufficient length.
For more information, see the cable details:
•
AC power cable using IEC C13 inline socket, page 137
2
Connect the ground cables.
a
If applicable, connect the ground cable from the display to vessel ground. (C3)
b
Connect the ground cable from the Processor Unit to vessel ground. (C4)
These cables must be provided by the installation shipyard. For more information,
see the cable details:
•
3
Connect the video cable from the Processor Unit to the display. (C5)
The display cable is often physically attached to the display, and terminated in the
“computer end” with a male connector. If the cable is not attached, it is normally
provided with the display.
The graphic adapter on the rear side of the Processor Unit provides two DVI
connectors, one for HDMI and two for Mini DisplayPort. Choose the connector
that fits your display cable. If you have two displays both can be connected
simultaneously, and can use the operating system functionality to set up different
presentations.
Keep the display cable as short as possible. If the cable is too long, it may pick up
electric noise, and this will reduce the image quality.
For more information, see the cable details:
•
Processor Unit graphic adapter, page 112
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...