394149/D
293
Wide Band Transceiver (WBT) power requirements
•
Make and model
: Simrad Wide Band Transceiver (WBT)
•
Voltage requirement
: 12 – 15 VDC, 5A
A suitable power supply is provided with the delivery.
•
Power Supply Unit
:
–
Make and model
: WBT Power supply
–
Voltage requirement
: 115/230 VAC, 47 to 63 Hz, single phase, nominal
–
Maximum voltage deviation
: 15%
–
Maximum transient
: 20% of nominal voltage, recovery time 3 s
–
Power consumption
: 100 VA (Approximately)
Related topics
Power requirements, page 292
Technical specifications, page 279
WBT Power Supply power requirements
•
Make and model
: WBT Power supply
•
Voltage requirement
: 115/230 VAC, 47 to 63 Hz, single phase, nominal
•
Maximum voltage deviation
: 15%
•
Maximum transient
: 20% of nominal voltage, recovery time 3 s
•
Power consumption
: 100 VA (Approximately)
Related topics
Power requirements, page 292
Technical specifications, page 279
LBG408A-R2 Ethernet switch power requirements
The technical specifications are those valid for the Ethernet switch that was delivered
from Kongsberg Maritime as a part of the EK80 delivery. For specifications related to a
locally purchased Ethernet switch, refer to the documentation provided with the unit.
•
Manufacturer
: Black Box
•
Manufacturer’s website
:
•
Make and model
: Black Box LBG408A-R2
•
Voltage requirement
: 100 - 240 VAC
•
Power consumption
: 15 W (Maximum)
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...