170
394149/D
that where crimped terminations are used, the correct size of crimp and crimping tool are
used. In addition, each cable conductor must have a minimum of 15 cm slack (service
loop) left before its termination is fitted.
Related topics
Basic cable requirements, page 167
Cable layout and interconnections, page 85
Cable identification
Cable identification codes corresponding to the cable number shown in the cable plan
must be attached to each of the external cables.
The identification codes should be positioned on the cable in such a way that they are
readily visible after all panels have been fitted.
In addition, each cable conductor should be marked with the terminal board number or
socket to which it is connected.
Related topics
Basic cable requirements, page 167
Cable layout and interconnections, page 85
Cable glands and termination procedures
Cable glands are used to attach and secure the end of a cable to the equipment. Cable
glands may also be used for sealing cables passing through bulkheads or gland plates.
Related topics
Basic cable requirements, page 167
Cable layout and interconnections, page 85
About cable glands
Cable glands are used whenever a cable passes through a watertight bulkhead or into
a cabinet, to seal the opening through which the cable passes and to protect the cable
from abrasion on the edges of the hole.
There are many different types of cable gland on the market. The cable glands are not
supplied with the system.
Note
Even though the cabinets from Kongsberg Maritime may be prepared for specific types
of cable glands, the installation shipyard will be responsible for selecting cable gland
types and installing them.
Simrad EK80 Installation Manual
Summary of Contents for Simrad EK80
Page 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Page 2: ......
Page 12: ...10 394149 D Simrad EK80 ...
Page 313: ...394149 D 311 Drawing file ...
Page 314: ...312 394149 D Simrad EK80 Installation Manual ...
Page 317: ...394149 D 315 Drawing file ...
Page 318: ...316 394149 D Simrad EK80 Installation Manual ...
Page 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Page 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Page 353: ......
Page 354: ...Installation Manual Simrad EK80 ...