4.2
Special parameters: SERCSET and BUSPx
SERCSET
Bit
Meaning
Value
24-31
IDN 76
0xFF00 0000
23
AT Status Bit 2 "Drive follows setpoints"
0x0080 0000
22
free
0x0040 0000
21
free
0x0020 0000
20
IDNP 3040 quadratic interpolation
0x0010 0000
19
IDNP 3059 external feed forward torque and velocity
0x0008 0000
18
IDNP 3059 external feed forward torque
0x0004 0000
17
Unassigned
0x0002 0000
16
SLEN binary
0x0001 0000
12-15
IDN 43 V-polarities
0x0000 F000
4-11
IDN 55 P-polarity, bit 8 is software limit switch
0x0000 0FF0
3
IDNP 3052 acceleration pilot control
0x0000 0008
2
IDNP 3028 output stage enable sequence
0x0000 0004
1
IDNP 3016 prevent coldstart (on/off)
0x0000 0002
0
IDNP 3015 consequence of the hardware limit switch 0x0000 0001
BUSPx
Parameter
Meaning
BUSP0
IDN 97 = 0x0000FFFF
IDN 98 = 0xFFFF0000
BUSP 1
Delay of external feed forward and move of time t3
BUSP 2
IDN 15 = 0x000000FF
IDN 32 = 0x00FF0000
BUSP 3
IDN 121 - input revolutions of load gear
BUSP 4
IDN 122 - output revolutions of load gear
BUSP 5
IDN 123 - feed constant
BUSP 6
IDN 79 - rotational position resolution
BUSP 7
IDN 117 - resolution of rotational feedback 2 (External Feedback)
BUSP 8
IDN 138 - nipolaracceleration limit value
BUSP1
Bit
HEX
DEZ
Meaning
0
0x0000 0001
1
Torque feed forward 1 cycle longer
1
0x0000 0002
2
Torque feed forward 1 cycle shorter
2
0x0000 0004
4
Velocity feed forward 1 cycle longer
3
0x0000 0008
8
Velocity feed forward 1 cycle shorter
4
0x0000 0010
16
1 further cycle of deceleration, if using non-quadratic interpolation
5
0x0000 0020
32
Target position value + 4 cycles of deceleration for pilot controls
6
0x0000 0040
64
Target position value + 5 cycles of deceleration for pilot controls
7
0x0000 0080
128
Target position value + 6 cycles of deceleration for pilot controls
8
0x0000 0100
256
T3 = T2 (MDT timing) + 50µs
only at 500µs cycle time
9
0x0000 0200
512
T3 = 100µs
only at 500µs cycle time
10
0x0000 0400
1024
T3 = 200µs
only at 500µs cycle time
11
0x0000 0800
2048
T3 = 300µs
only at 500µs cycle time
12
0x0000 1000
4096
T3 = 510µs
only at 500µs cycle time
13
0x0000 2000
8192
Actual position value deceleration by 1 sercos
®
cycle
14
0x0000 4000
16384 Actual position value deceleration by 2 sercos
®
cycles
15
0x0000 8000
32768 reserved
16-27 0x0FFF 0000
T3 timing from and to IDNP 3062.
28-31 0xF000 0000
reserved
104
sercos
®
for S300/S700
Appendix
04/2016
Kollmorgen