Connector Pinout And Descriptions
4/13/2012
Kollmorgen
31
S200 Position Node Installation Guide
7.4 TB1: H
IGH
P
OWER
AC P
OWER
C
ONNECTIONS
Models: S21260-xNS
The S200 AC input drives are capable of direct line operation. All units are fully isolated and do not require
external isolation transformers. The inrush current on the connection to the line is internally limited to a safe level
for the drive. There are no voltage selection or ranging switches required to operate within the specified voltage
input ranges.
TB1 High Power AC Units Power Connection
1 PE
Protective Earth (Motor Cable Shield Connection)
2 W
Motor Output Phase W
3 V
Motor Output Phase V
4 U
Motor Output Phase U
5 Regen Optional Regen Resistor Connection (See Wiring Detail Section)
6 - Bus Main DC Bus – Output (Normally not connected)
7 + Bus Main DC Bus + Output (Normally connected with Optional Regen)
8 L3
Mains L3 Incoming Power Connection
9 L2
Mains L2 Incoming Power Connection
10 L1
Mains L1 Incoming Power Connection
Please refer to the Specifications section for fusing and rating information.
The S200 series drives are functionally compatible with all standard forms of
three phase AC lines:
Grounded neutral WYE
Open-Delta Grounded Leg
TEE
NOTE
It is the customer’s responsibility to supply appropriate fuses or circuit
breakers in the TB1 AC drive power lines to comply with local electrical codes.
PE
W
V
U
Regen
-Bus
+Bus
L1
L2
L3