Detailed Wiring Information
4/13/2012
Kollmorgen
44
S200 Position Node Installation Guide
9.4.2 Typical Wiring with Sourcing Switches
The above diagram shows typical wiring for Sourcing switches. The Switches supply the source of current through
the S200 Position Node input. These devices may be solid state and are sometimes called PNP devices.
Current drain for the inputs is identified in the following table.
Input Voltage (±)
Input Current (±)
4.0 volts
0.65 mA
5.0 volts
0.95 mA
12 volts
2.5 mA
24 volts
5.3 mA
30 volts
6.7 mA
9.4.3 Wiring DINP5 and DINP10
As noted DINP5 and DINP10 are high speed opto-isolated input devices that do not have a connection to a
common rail. They are designed for 5 volt operation and the polarity of the power supply used is critical for
functionality. Not having a common rail connection the inputs can be wired for sourcing or sinking according to the
need of the application.
+
-
Internal Opto-Isolators
DINP1
(Enable)
(DINP6)
DINP2
(DINP7)
DINP3
(DINP8)
DINP4
(DINP9)
S200 Position Node Internal Equiv
Circuits
Customer’s Power Supply
4 to 30Vdc
Field Wiring
Customer’s Switching
(May be Solid State)
J4-1
(J12-1)
J4-2
(J12-2)
J4-3
(J12-3)
J4-4
(J12-4)
J4-5
(J12-5)
DINP5
(DINP10)
S200 Position
Node Internal
Hi-Speed Opto-Isolator
Field Wiring
Customer’s Power Supply
5Vdc
J4-10
(J12-10)
J4-11
(J12-11)