Goldline EB Instructions | 3 Technical Data
3.1 General Technical Description
Technical data for every motor type can be found in this chapter. See
,
Motor Specifications For EB-20x
Motor Specifications For EB-40x
,
, and
Motor Specifications For EB-80x
for more information.
Ambient temperature
(at rated values)
l
5...+40°C for site altitude up to 1000m amsl
l
It is vital to consult our applications department for ambient
temperatures above 40°C and encapsulated mounting of the motors.
Permissible humidity
(at rated values)
l
95% rel. humidity, no condensation
Power De-Rating
(Current and Torque)
l
for site altitude above 1000m amsl and 40°C:
l
6% up to 2000m amsl
l
17% up to 3000m amsl
l
30% up to 4000m amsl
l
55% up to 5000m amsl
Ball-bearing life
l
≥ 20.000 operating hours
Protection Class
Standard Motor
Connector Option
Shaft Seal
Protection class
EB
1
without*
IP40
l
Shaft seal option is not available for EB Series units.
l
Code "4" protects from objects greater than 1mm.
l
Code "0" states the device is not protected against liquid.
Insulation Material
class
l
The motors come up to insulation material class F according to IEC 60085
(UL1446 class F).
32
Kollmorgen | kdn.kollmorgen.com | August 2021
Summary of Contents for EB-10 Series
Page 19: ...2 1 1 Goldline EB Instructions 2 Kollmorgen kdn kollmorgen com August 2021 19...
Page 30: ...Goldline EB Instructions 2 30 Kollmorgen kdn kollmorgen com August 2021...
Page 74: ...Goldline EB Instructions 3 Technical Data 74 Kollmorgen kdn kollmorgen com August 2021...
Page 92: ...Goldline EB Instructions 4 Dimension Drawings 92 Kollmorgen kdn kollmorgen com August 2021...
Page 94: ...Goldline EB Instructions 5 Leadwire Diagram 94 Kollmorgen kdn kollmorgen com August 2021...