AKD Installation | 5 Approvals
5.2 Conformance with CE
Conformance with the EC EMC Directive 2014/30/EC and the Low Voltage Directive
2014/35/EC is mandatory for the supply of drives within the European Community.
CE Declarations of Conformity can be found on the Kollmorgen website.
The drives have been tested by an authorized testing laboratory in a defined configuration,
using the system components that are described in this documentation. Any divergence from
the configuration and installation described in this documentation means that the user will be
responsible for carrying out new measurements to ensure conformance with regulatory
requirements.
Kollmorgen declares the conformity of the product series AKD with the following directives:
EC Directive 2006/42/EC, Machinery Directive
Used harmonized standard EN61800-5-2 (2007)
EC Directive 2014/35/EC, Low Voltage Directive
Used harmonized standard EN61800-5-1 (2007)
EC Directive 2014/30/EC, EMC Directive
Used harmonized standard EN 61800-3 (2004)
These devices can cause high-frequency interferences in non industrial environments and
may require measures for interference suppression (such as additional external EMC filters).
AKD-xzzz06
AKD-xzzz06 drives do not have integrated EMC filters.
With external EMC filters for noise emission the AKD-xzzz06 meet the noise immunity
requirements of the second environmental category (industrial environment) to a product of
the category C2 (motor cable < 10 m).
With a motor cable length of 10 m or longer and external EMC filters, the AKD-xzzz06 meet
the requirement of category C3.
AKD-xzzz07
AKD-xzzz07 drives have integrated EMC filters.
The AKD-xzzz07 meet the noise immunity requirements to the 2nd environmental category
(industrial environment). For noise emission the AKD-xzzz07 meet the requirement to a
product of the Category C2 (motor cable < 10 m).
With a motor cable length of 10 m or longer, the AKD-xzzz07 meet the requirement to the Cat-
egory C3.
AKD-x04807: In case of mains voltage asymmetry >3% a mains choke 3L0,24-50-2 must be
used.
26
Kollmorgen | kdn.kollmorgen.com | October 2017