9.14.10 Digital Relay Outputs 25, 30
The drive option "IC" provides two digital outputs, which are signaled by floating relay con-
tacts(
# 146). Choose the required function in the setup software. Messages from pre-pro-
grammed functions stored in the drive can be output here. A list of these pre-programmed
functions can be found in the setup software. If an output is to be assigned to a pre-pro-
grammed function, then the parameter set must be saved in the drive.
Technical characteristics
Relay output, max. 30 VDC or 42 VAC, 1 A
Time to close: max. 10 ms
Time to open: max. 10 ms
Wiring diagram
AKD Installation | 9 Electrical Installation
Kollmorgen | kdn.kollmorgen.com | October 2017