AKD Installation | 9 Electrical Installation
9.14 I/O Connection
9.14.1 Overview
9.14.1.1 I/O connectors X7 and X8 (all AKD variants)
Standard digital and analog I/O signals are connected to X7 and X8.
AKD-B , -P, -T
Conn.
Pin
Signal
Abbreviation
Function
Wiring
Diagram
X7
1
Digital Common X7
DCOM7
Common line for
X7 pins 2, 3, 4, 9, 10
X7
2
Digital Input 7
DIGITAL-IN 7
Programmable
X7
3
Digital Input 4
DIGITAL-IN 4
Programmable
X7
4
Digital Input 3
DIGITAL-IN 3
Programmable
X7
5
Digital Output 2-
DIGITAL-OUT2-
Programmable
X7
6
Digital Output 2+
DIGITAL-OUT2+
Programmable
X7
7
Digital Output 1-
DIGITAL-OUT1-
Programmable
X7
8
Digital Output 1+
DIGITAL-OUT1+
Programmable
X7
9
Digital Input 2
DIGITAL-IN 2
Programmable,fast
X7
10
Digital Input 1
DIGITAL-IN 1
Programmable,fast
X8
1
Fault Relay Output Fault Relay Output
Fault Relay Output
X8
2
Fault Relay Output Fault Relay Output
Fault Relay Output
X8
3
Digital Common X8
DCOM8
Common line for
X8 pins 4, 5, 6
X8
4
Digital Input 8
DIGITAL-IN 8
Output stage enable,
not programmable
X8
5
Digital Input 6
DIGITAL-IN 6
Programmable
X8
6
Digital Input 5
DIGITAL-IN 5
Programmable
X8
7
Analog Ground
AGND
Analog GND
X8
8
Analog
Analog-Out
Actual velocity voltage
X8
9
Analog Input -
Analog-In-
Velocity set point
X8
10
Analog Input +
Analog-In+
Digital common lines for X7 and X8 are not common to each other.
The DCOMx line should be connected to the 0V of the I/O supply when using sensors of type
"Source" with digital inputs.
The DCOMx line should be connected to the 24V of the I/O supply when using sensors of
type "Sink" with digital inputs.
146