10.3.3 Software description
Each drive must be adapted to the requirements of your machine. For most applications, you
can use a PC and KAS IDE software ("Kollmorgen Automation Suite Integrated development
environment) to set up the operating conditions and parameters for your drive. The PC is con-
nected to the drive by an Ethernet cable (
# 171). The setup software provides the com-
munication between the PC and AKD PDMM. You can find the KAS IDE setup software on
the accompanying DVD and in the download area of the Kollmorgen website.
With very little effort you can alter parameters and instantly observe the effect on the drive,
since there is a continuous (online) connection to the drive. You can also read important
actual values from the drive, which are displayed on the monitor of the PC (oscilloscope func-
tions).
You can save sets of data on data media (archiving) and load them into other drives or use
them for backup. You can also print out the data sets.
Most standard feedbacks (SFD, EnDAT 2.2, 2.1, and BiSS) are plug and play compatible.
Motor nameplate data is stored in the feedback device and read by the drive automatically at
startup. Non-plug and play Kollmorgen motors are stored in KAS IDE and can be loaded with
one-click using the Motor screen in the KAS IDE software.
An extensive online help with integrated description of all variables and functions supports
you in each situation.
10.3.4 Hardware requirements
The Service interface (X32, RJ45) of the drive is connected to the Ethernet interface of the
PC by an Ethernet cable (
Minimum requirements for the PC:
Processor: at least Pentium
®
II or higher
Operating system : Windows XP or 7
Graphics adapter : Windows compatible, color
Drives : hard disk with at least 20 MB free space, DVD drive
Interface : one free Ethernet Interface, or a Hub port or Switch port
10.3.5 Operating systems
Windows XP/7
KAS IDE works with Windows XP and Windows 7
Unix, Linux
The functioning of the software has not been tested for Windows running within Unix or
Linux.
AKD Installation | 10 Setup
Kollmorgen | kdn.kollmorgen.com | October 2017
193