14-4
Program operating mode
Page 2 - Sample (Sound Programs)
ing on the number of oscillators used by the
Program (a maximum of 62 with only 1 oscil-
lator, or a maximum of 15 with 4 oscillators).
Mode
This is the polyphonic mode of the Program.
Poly
The Program will play in polyphonic mode,
allowing you play chords.
Mono
The Program will play in monophonic mode,
producing only one note at a time.
Single Trigger
This parameter is available when the “Mode” parameter is set
to Poly.
Yes
When the same note is played repeatedly, the
previous note will be silenced before the next
note is sounded, so that the notes do not over-
lap.
No
When the same note is played repeatedly, the
previous note will not be silenced before the
next note is sounded.
Legato
This parameter is available when the “Mode” parameter is set
to Mono.
Yes
Legato is on. When multiple note-on occur,
the first note-on will retrigger the sound, and
the second and subsequent note-on will not
retrigger.
When legato is on, multiple note-on will not
retrigger the voice. If one note is already on
and another note is turned on, the first voice
will continue sounding. The oscillator sound,
envelope, and LFO will not be reset, and only
the pitch of the oscillator will be updated. This
setting is effective for wind instrument sounds
and analog synth-type sounds.
No
Legato is off. Notes will always be retriggered
when note-on occurs.
When legato is off, multiple note-on will
retrigger the voice at each note-on. The oscilla-
tor sound, envelope, and LFO will be reset
(and retriggered) according to the settings of
the Program.
Note:
If “Legato” is On, certain multisamples or keyboard loca-
tions may produce an incorrect pitch.
Priority
This parameter is available when the “Mode” parameter is set
to Mono. It specifies which note will be given priority to play
when two or more notes are played simultaneously.
Low
Lowest note will take priority.
High
Highest note will take priority.
Last
Last note will take priority.
PAGE 2 - SAMPLE (SOUND PROGRAMS)
The multisample(s) (waveform) on which the Program will
be based can be selected here for each of the four oscillators.
Each oscillator can use 1 or 2 multisamples, each one
assigned to the High or Low layer.
The internal Flash-ROM contains 340 different multisamples
(preset multisamples). By selecting a CARD multisample,
you can use a multisample read from the Card (if inserted in
the slot). The card option is reserved for future development.
Selected
Use this parameter to select an oscillator to put in edit. Alter-
natively, you can select oscillators using the F1-F4 buttons.
MS Hi/Lo Bank/Num
Use these parameters to select a different multisample for
each of the High and Low layers. You can use velocity to
switch between the two multisamples. Reverse, Offset and
Level can be adjusted independently for the High and Low
multisamples.
The first line is where you select the bank (ROM or CARD),
while the second line is for selecting the multisample. The
Program number appears at the end of the second line.
The multisample you select for the High layer will be trig-
gered by velocities higher than the value of the “Velocity
Switch” parameter (see page 14-5). If you do not wish to use
velocity switching, set the switch to a value of 001, and select
only the High multisample.
ROM
Select a preset multisample.
CARD
Select a Card multisample (not available yet)
Note:
If you create a new Program based on a
Card multisample, the card must be inserted
before selecting the Program, or no sound will be
heard.
Note:
Each multisample has an upper limit, and may not pro-
duce sound when played above that limit.
[H/L] Reverse
The multisample will be played in reverse. In the case of
Flash-ROM or optional (CARD) multisamples that were
originally specified to loop, the multisample will be played
back in “one-shot” reverse mode. If the multisample was
originally set to reverse, it will playback without change.
Yes
The multisample will playback in reverse.
No
The multisample will play back normally.
Selected: Osc1
MS Hi Bank/Num: ROM
L>AcousticPiano 0
[H] Reverse: No
Samples |Osc1
Summary of Contents for KD-150
Page 1: ......
Page 5: ......
Page 11: ...TOC 6 ...
Page 12: ...INTRODUCTION ...
Page 13: ......
Page 29: ...4 4 Display and User Interface Grayed out non available parameters ...
Page 32: ...BASIC GUIDE ...
Page 33: ......
Page 39: ...6 6 Basic operations Shortcut to see the original bank for a Style Performance or Program ...
Page 47: ...7 8 Tutorial 5 Editing a Song ...
Page 53: ...8 6 MIDI Playing another instrument with the KD ...
Page 54: ...REFERENCE GUIDE ...
Page 55: ......
Page 103: ...11 14 Song Play operating mode Saving a list of Songs ...
Page 111: ...12 8 Backing Sequence operating mode How to delete a whole Song ...
Page 133: ...13 22 Song operating mode Event Edit procedure ...
Page 189: ...16 20 Disk edit environment Page 11 Card Restore ...
Page 190: ...APPENDIX ...
Page 191: ......
Page 225: ...17 34 Factory Data MIDI Setup ...
Page 283: ...18 58 Effects Mono Mono Chain ...
Page 287: ...19 4 Assignable parameters Scales ...
Page 303: ...24 2 Technical specifications ...