7.5
Section 7
Retractable Starter
7
Figure 7-11. Torque Center Mounting Screw.
6. Tension the spring and install the rope and handle
as outlined in Steps 6 through 12 under ‘‘Rope
Replacement.’’
7. Install the recoil starter to engine blower housing
but do not fully tighten the mounting screws.
8. Pull out on recoil handle/rope to engage the pawls
to the drive cup, hold engaged and torque the
mounting screws to 5.5 N·m (47.7 in. lbs.). See
Figure 7-3.
3. Carefully install pulley into recoil housing,
engaging the spring hook with starter housing tab.
See Figure 7-10.
NOTE: Rotating pulley counterclockwise slightly
will assist engagement.
4. Install the pawl springs (CS8.5-12 only) and pawls
onto pawl studs of pulley.
Figure 7-10. Assembling Starter Pulley to Housing.
5. Mount drive plate over pawls onto pulley, aligning
the actuating slots in plate with the raised sections
on each drive pawl. Torque the screw to
5-6 N·m (44-53 in. lbs.). Rotate the pulley by
hand and check operation. See Figure 7-11.