To service the precleaner perform the following steps:
1. Remove the air cleaner cover knob (standard air
cleaner) or unsnap the latches (heavy-duty air
cleaner), and remove the cover/housing. See
Figures 4-3 and 4-4.
2. Remove the precleaner from the filter element. If
element is not secured to the air cleaner base
with a wing nut, remove the filter element and
precleaner from the cover/housing, as an
assembly before separating. See Figures 4-5 and
4-6.
3. Wash the precleaner in warm water with
detergent. Rinse the precleaner thoroughly until
all traces of detergent are eliminated. Squeeze
out excess water (do not wring). Allow the
precleaner to air dry.
4. Saturate the precleaner with new engine oil.
Squeeze out all excess oil.
5. Install the precleaner over the paper element. If
the element was not secured with a wing nut
(some heavy-duty air cleaners) install the
element/precleaner assembly, small end first, into
the cover/housing.
6. Reinstall the air cleaner cover/housing assembly.
Secure with the knob or latches.
Figure 4-5. Standard Element/Precleaner Assembly.
Figure 4-4. Unsnapping Heavy-Duty Latches.
Figure 4-7. Removing Standard Precleaner.
Figure 4-6. Heavy-Duty Element/Precleaner
Assembly.
Precleaner Service
If so equipped, wash and reoil the precleaner every 25
hours of operation (more oftern under extremely dusty
or dirty conditions).
Summary of Contents for COMMAND PRO CS10
Page 1: ...SERVICE MANUAL COMMAND PRO CS SERIES 4 12 HP HORIZONTAL CRANKSHAFT...
Page 20: ...1 18 Section 1 Safety and General Information...
Page 24: ...2 4 Section 2 Special Tools...
Page 48: ...6 4 Section 6 Lubrication System...
Page 54: ...7 6 Section 7 Retractable Starter...
Page 84: ...8 30 Section 8 Electrical System and Components...
Page 106: ...9 22 Section 9 Disassembly...