MDC-3560P/3510P Series
Chapter 3
TECHNICAL SPECIFICATIONS
93142002-01
3-3
3.5 Power Supply
Mains Input Voltage:
24 VDC / 32 VDC
Input Voltage Tolerance:
21.6 VDC – 41.6 VDC (24 V/32 V, -10%, +30%)
Input Power:
130 W nominal at 24 VDC
Transient Protection:
To the requirements of IEC 60945 3
rd
Edition.
Reversed polarity protection:
Protected by the Main Fuse.
AC Operation
Rectifier Unit Type PS-010 is required.
Input voltage range: 115/230 VAC
Input voltage tolerance: +/- 10%
Input voltage frequency range: 47 to 63 Hz
Input Power: 220 W
3.6 Compass Safe Distance
Component Unit
Type Name
Standard
Steering
Antenna
RB717AP/RW701A-04
1.4 m
0.95 m
RB717AP/RW701A-06
1.4 m
0.95 m
RB718AP/RW701A-04
1.4 m
0.95 m
RB718AP/RW701A-06
1.4 m
0.95 m
Display
MRD-98P
1.55 m
0.75 m
3.7 Environmental specification
To the requirements of IEC 60945 3
rd
Edition. The measure environmental
specifications are as follows:
(1) Temperature and humidity
Operating temperature
Storage temperature
Humidity
Antenna -25
o
C - +55
o
C +77
o
C
93%+/-3% at +40
o
C
Display -15
o
C - +55
o
C +55
o
C
93%+/-3% at +40
o
C
(2) Vibration
2-5Hz up to 13.2 Hz: Amplitude +/-1mm +/-10% (Maximum acceleration 7m/s
2
at
13.2Hz)
13.2 Hz up to 100Hz: Maximum acceleration 7 m/s
2
constant