background image

AR-3300 & AR-3500  Alignment Procedures

 

 

SYNTHESIZER

 

 

1. - Set radio to 29.9000 Mhz. FM mode.

 

2. -

 Connect DVM to TP-1 and adjust T-13 for 3.8 VDC. 

3. -

 

Set the radio to 28.0000 Mhz

( Clarifier Center )

 

4. -

 Connect Scope to 

TP-2.

 Adjust 

T-12

 for Max in AM mode. 

5. -

 Connect Scope to cathode of 

D-77.

 Adjust 

T-11

 for Max in AM mode. 

 

NOTE : Step 2 of SSB Transmitter Alignment should be done at this time as it effects 

10.695 Mhz. Oscillator adjustment.

 

 

Please note that radios with the optional 2.6 Khz. SSB filter use different offset 

frequency adjustments. The filter can be identified by the markings on the top. 

( 10M2.6D 

is the 2.6 filter ).

 

 

6. -

 Connect frequency counter to 

TP-3

 

( High impedence probe ).

 

 
                

4.2 Khz

.                      

2.6 Khz

.

 

 

A. -

 Adjust 

T-16

 for 

10.6925

 -- or - 

10.6935

 in 

USB

 mode. 

B. -

 Adjust 

T-17

 for 

10.6975

 -- or - 

10.6965

 in 

LSB

 mode. 

C. -

 Adjust 

T-15

 for 

10.6943

 -- or - 

10.6943

 in  

CW

 mode. 

D. -

 Adjust 

T-14

 for 

10.6950

 -- or - 

10.6950

 in 

 AM TX

 mode. 

 

7. -

 Connect frequency counter to 

TP-2

 
                

4.2 Khz

.                      

2.6 Khz

.

 

 

A. -

 Adjust 

VR-3

 for 

17.3050

 -- or -- 

17.3050

 in  

FM

 mode. 

B. -

 Adjust 

VR-1

 for 

17.3075

 -- or -- 

17.3065

 in 

USB

 mode. 

C. -

 Adjust 

VR-2

 for 

17.3025

 -- or -- 

17.3035

 in 

LSB

 mode. 

 

8. -

 Adjust 

T-14

 for output freq. of 

28.0000 Mhz.

 FM mode. 

 

RECEIVER

 

 

IF ( 10.695 Mhz.)

 

 

1. -

 Set radio in 

AM

 mode. Apply a 

10.6950 Mhz. ( AM modulated at 60% )

 signal from 

signal generator through a 10 to 1 probe to the 

emitter of Q-2.

 ( Output of Signal 

Generator should be just enough to produce output at speaker, about 

12 db. Sinad.)

 

 

2. -

 Adjust 

T-4, T-5, T-8, T-9, and T-10

 for Max AF output. 

 

NOTE : Any excessive Signal Generator output will activate AGC and cause a false 

alignment.

 

 

3. -

 Set radio to CW mode, Signal generator to 0% modulation. Adjust T-6 & T-7 for max 

audio output. 

 

NOISE BLANKER

 

 

1. -

 Connect a noise generator ( Sencore NL 204 or equivalent ) in series with signal 

generator output. Connect Scope to 

TP-4.

 Set signal generator for 

20 uV.

 output. Adjust 

T-400 & T-401

 for Max peaks. 

 

HIGH FREQUENCY

 

 

1. -

 Set radio to 

28.0000 Mhz. on AM mode.

 

2. -

 Apply a 28.0000 Mhz. 

( AM modulated at 60% )

 signal to antenna. 

Reviews: