MDC-3560P/3510P Series
Chapter 6
USING THE MENU
93142002-01
6-23
[ALARM])
6.2.19 ALARM TEST (Testing the alarm function)
This function is used to verify that the alarm function is in normal order. Carry out the
following operation to perform this function.
(1) Highlight the OFF sign shown right of the words ALARM TEST.
(2) Press the ENT key to set the selection ready status.
(3) Press the joystick either to the left or the right to select the ON sign.
(4) Press the ENT key to fix the selection. The blinking ON sign will become stationary
and the alarm test will start.
(5) In approximately 10 seconds, various alarm messages will be shown and an audio
alarm will be activated. (NOTE: NO audio alarm sounds if the BUZZER OFF status
is activated)
(6) To cancel the ALARM TEST function, set the ALARM TEST mode to OFF, set the
radar to standby mode once, and then transmit again.
[ATA TARGET LEVEL]
6.2.20 TGT LEVEL (Setting the target level for ATA)
This function is used to set the signal level that will be fed into the ATA system. Use
the following procedure to select the signal level.
(1) Highlight the figure (0 – 7) shown right of the TGT LEVEL. The signal level
increases in an ascending order.
(2) Press the ENT key to set the ready to select status.
(3) Press the Joystick either right or left to select an appropriate level and press the
ENT key. The blinking figure will become stationary and the set level will be
entered.
[CRT]
6.2.21 DEGAUSS (Canceling the CRT magnetism)
This function is used to cancel the magnetization on the Cathode Ray Tube that may
cause color deviation on the screen. The degaussing is automatically performed when
the radar is switched from Standby to On or On to Standby. The degaussing can also
be carried out anytime while the radar is operated. Highlight the DEGAUSS sign and
press the ENT key. Allow 10 seconds before carrying out the next degaussing.