MDC-3560P/3510P Series
Chapter 5
BASIC OPERATION
93142002-00
5-11
anti-clutter sea control is defaulted to manual mode. To set the auto Anti-clutter
mode, press the top end of the SEA control. The receiver gain will be automatically set
and the manual SEA clutter control will accordingly become inactive. The first press
introduces the Harbor STC that provides a preset Anti-clutter sea effect, optimized for
narrow areas. The second press introduces the Automatic STC that provides a
hands-free Anti-clutter sea effect. A subsequent press of the control changes the
mode display to HARBOR, SEA AUTO and SEA MANUAL in sequence. In Harbor and
Auto Anti-clutter Sea modes, the manual control is set ineffective.
5.5.5 Anti-clutter RAIN control
The RAIN control is used to reduce the clutter echo appearing on the screen caused
by the rain or snow. The effect of the anti-clutter rain control increases as you turn the
control clockwise and is the greatest at a fully clockwise position. The anti-clutter
RAIN control can be switched to either a manual or auto mode by pressing the RAIN
control knob.
The control mode toggles each time you press the control. When first turned on, the
anti-clutter RAIN function is defaulted to manual mode. To set the auto RAIN-clutter
control, press the control knob. The clutter echo from rain or snow will be reduced
automatically and the manual rain clutter control will become inactive.
5.5.6 Bearing measurement using a single EBL
(1) Press the EBL ON/OFF key to show EBL on the screen. The EBL will be
displayed in a dashed line with the bearing display in the bottom left of the
screen. An arrow mark will be shown on the front of the digital display to indicate
the EBL is active.
(2) Select the bearing mode if necessary, either RELATIVE or TRUE by pressing
the
TRUE/REL
key.
(3) Rotate the EBL control to measure the bearing of a target. To measure a single
target, always set the EBL on the center of the target. To measure the bearing of
the edge of a landmass, move EBL towards the inside of the landmass by half of
the aerial horizontal beam width.
(4) To erase the EBL, press the EBL ON/OFF key again.
5.5.7 Bearing measurement using two EBLs
(1) Press and hold the HL OFF key then press the EBL ON/OFF key. The 2
nd
EBL
will be shown with the 1
st
EBL in a dotted line with the bearing display underneath
the
1
st
EBL bearing display. An arrow mark will be shown on the front of the digital
display to indicate the selected EBL is active.