Chapter 5
MDC-3560P/3510P Series
BASIC OPERATION
5-6
93142002-00
OFFSET key
UPDATE key
DELETE key
ACQ key
TARGET
TARGET key
TRUE/REL key
ALARM (GZ) key
HL OFF
OFFSET
UPDATE
DELETE
ACQ
TARGET
TRUE
REL
ALARM
(GZ)
The OFFSET key is used to set the EBL 1 and VRM 1 off-centered
on the screen. Every press of the key toggles the EBL 1 and VRM 1
off-centered and centered.
The UPDATE key is used in the EPA function, in conjunction with
the TARGET key and Joystick, to correct a plotted target position.
For detail, refer to Para 6.1.16.11 “Correcting the latest plotting
position”.
The DELETE key is used in the EPA/ATA function, in conjunction
with the TARGET key, to cancel a plotted target. For detail, refer to
Para. 6.1.16 Operation of EPA or Para. 6.1.17 Using ATA.
The ACQ key is used in the EPA/ATA function, in conjunction with
the TARGET key, to acquire a target for tracking. For detail, refer
to Para. 6.1.16 Operation of EPA or Para. 6.1.17 Using ATA.
The TARGET key is used in the EPA/ATA function, to assign the
target number to acquire, delete or display the ATA/EPA information
of each tracked target. For detail, refer to Para. 6.1.16 Operation of
EPA or Para. 6.1.17 Using ATA.
The TRUE/REL key is used to change the picture mode to either
the True or Relative bearing. Each press of this key changes the
bearing mode of the radar picture, EBL, Parallel Index and the EPA
or ATA target vectors to Relative or True.
The ALARM key is used to turn on and off the Guard Zone Alarm.