Appendix H. Error Message
H-3
7. Gross Units Over
Explanation
The calculated gross weight (or selected
engineering unit) exceeds six active digits
(999999).
Solutions
Note
Write down all existing system
parameters before you change the
Form
or
Units
. If you change the
Form
or
Units
you must adjust system
parameters to correspond to the new
Form
or
Units
.
1. Check the
Form
you selected for the
channel. A form of xxxx.xx yields a
maximum value of 9999.99, while a form of
xxxxx00 yields a maximum value of
99999900. Make sure that the form is
consistent with the maximum expected
value.
2. Check the
Units
you selected for the
channel. For example, a value in tons is
2000 times greater than a value in pounds;
a value in barrels is 42 times greater than
a value in gallons. Make sure that the units
are consistent with the maximum ex-
pected value.
3. Check the calibration for the channel.
Recalibrate if required.
8. Net Units Over
Explanation
The calculated net weight (or selected
engineering unit) exceeds six active digits
(999999).
Solutions
Note
Write down all existing system
parameters before you change the
Form
or
Units
. If you change the
Form
or
Units
you must adjust the system
parameters to correspond to the new
Form
or
Units
.
1. Check the
Form
you selected for the
channel. A form of xxxx.xx yields a
maximum value of 9999.99, while a
form of xxxxx00 yields a maximum value
of 99999900. Make sure that the form
is consistent with the maximum expected
value.
2. Check the
Units
you selected for the
channel. For example, a value in tons is
2000 times greater than a value in pounds;
a value in barrels is 42 times greater than
a value in gallons. Make sure that the units
are consistent with the maximum ex-
pected value.
3. Check the calibration for the channel.
Recalibrate if required.
9. Math Channel Overrange
ChXX
Explanation
This error message applies to math channels
only. It indicates that one of the sensor input
channels used in the math formula is above
2,097,151 counts (if +) or 0 (if -). There will
be a corresponding ADC Overrange error
message on the sensor channel.
Solution
Determine which of the sensor input channels
has the overrange problem by scrolling to
each input channel to see if the ADC
Overrange message is displayed. Then, see
ADC Overrange above for correcting the
problem.
10. Math Channel Units Over
ChXX
Explanation
This error message applies to math channels
only. It indicates that the calculated net or
gross weight (or whatever engineering unit
you selected for the display) from one or
more of the sensor input channels used in the
math formula exceeds six active digits
(999999). There will be a corresponding
Gross or Net Units Over error message on
the sensor channel.
Solution
Determine which of the input channels has
the problem by scrolling to each input
channel to see which has the Gross Units
Over or Net Units Over message displayed.
Then, see Gross Units Over above for correct-
ing the problem.
Summary of Contents for Weigh II
Page 12: ...2 4 Chapter 2 Hardware Installation...
Page 20: ...3 8 Chapter 3 Menu Tree Keyboard Functions and Quick Start...
Page 50: ...6 12 Chapter 6 Calibration...
Page 68: ...A 2 Appendix A Product Specifications...
Page 70: ...B 2 Appendix B Summary of Commands Used When Vessel Mounting Hot Keys...
Page 77: ...Appendix E E 1 This appendix not used at this time...
Page 78: ...Appendix E E 2...
Page 80: ...Appendix F Technical Drawings F 2...
Page 81: ...Appendix F Technical Drawings F 3...
Page 82: ...Appendix F Technical Drawings F 4...
Page 83: ...Appendix F Technical Drawings F 5...
Page 84: ...Appendix F Technical Drawings F 6...
Page 85: ...Appendix F Technical Drawings F 7...
Page 86: ...Appendix F Technical Drawings F 8...
Page 87: ...Appendix F Technical Drawings F 9...
Page 88: ...Appendix F Technical Drawings F 10...
Page 89: ...Appendix F Technical Drawings F 11...
Page 90: ...Appendix F Technical Drawings F 12...
Page 91: ...Appendix F Technical Drawings F 13...
Page 92: ...Appendix F Technical Drawings F 14...
Page 93: ...Appendix F Technical Drawings F 15...
Page 94: ...Appendix F Technical Drawings F 16...
Page 95: ...Appendix F Technical Drawings F 17...
Page 96: ...Appendix F Technical Drawings F 18...
Page 97: ...Appendix F Technical Drawings F 19...
Page 98: ...Appendix F Technical Drawings F 20...
Page 99: ...Appendix F Technical Drawings F 21...
Page 100: ...Appendix F Technical Drawings F 22...
Page 101: ...Appendix F Technical Drawings F 23...
Page 102: ...Appendix F Technical Drawings F 24...
Page 103: ...Appendix F Technical Drawings F 25...
Page 104: ...Appendix F Technical Drawings F 26...
Page 105: ...Appendix F Technical Drawings F 27...
Page 106: ...Appendix F Technical Drawings F 28...
Page 107: ...Appendix F Technical Drawings F 29...
Page 108: ...Appendix F Technical Drawings F 30...
Page 109: ...Appendix F Technical Drawings F 31...
Page 110: ...Appendix F Technical Drawings F 32...
Page 116: ...Appendix G Calculation of Maunal Calibration Parameters G 6...