harmful to electronics.
Power Fuse
Information
There are two power fuse locations in the
Weigh II. Refer to Table 2-1 for specification
information on each fuse.
Table 2-1. Power Fuse Information
Installing PCBs
The Weigh II arrives from Kistler-Morse with
the specified PCBs installed. However, you
can expand your system by purchasing
optional PCBs and installing them into vacant
positions on the motherboard. There are three
positions on the motherboard of the Weigh II
that accept optional PCBs. Note the following
restrictions on PCB positions in the Weigh II:
•
Position 1
4-channel multivessel PCB
•
Position 2
5-channel or 8-channel Setpoint PCB
Allen-Bradley RIO PCB
Remote Tare PCB (up to 4-channels)
•
Position 3
5-channel or 8-channel Setpoint PCB
Allen-Bradley RIO PCB
Profibus DP
2-channel, 4-channel, or 8-channel
Current Transmitter PCB (for use only
with the AC power version of the
Weigh II)
Combi-Card PCBs
(2 setpoints and 1 current output;
4 setpoints and 1 current output;
or 4 setpoints and 2 current outputs)
A new PCB from Kistler-Morse comes with
the following items:
• PCB
• Two 4-40 x
1
/
4
PHS screws to secure the
PCB to the Weigh II motherboard
Refer to the applicable drawing in Appendix F
for PCB slot locations and wiring details and
follow this procedure to install a PCB into the
Weigh II:
1. Disconnect power to the Weigh II.
2. Open the door of the Weigh II.
3. Place the PCB in the designated position
on the motherboard. Be sure the PCB
connector inserts completely into the
motherboard connector.
4. Secure the PCB in place with the two
4-40 x
1
/
4
PHS screws supplied with
the PCB.
5. Connect the field wiring to the PCB.
6. Restore power to the Weigh II. Close the
door. Installation is complete.
If you add a 4-channel multi-vessel PCB to
the Weigh II, you must use the
Enab
and
Dflt
functions in the
ADC
Menu of the
Service
Menu to bring the new channels on-line. Refer
to Chapter 7, Service, for the use of those
functions.
Note
Before you use the
Dflt
function to
bring the new channels on-line,
write
down all calibration and setup
parameters
. The
Dflt
function will
erase all existing calibration and setup
parameters. Reenter the parameters
after the new channels are on-line.
Fuse Part No. Purpose Voltage Current
F1 18-1002-01
AC
250 V
1.0 A
F2 18-1033-13
DC
50 V
1.85 A
Chapter 2. Hardware Installation
2-3
Summary of Contents for Weigh II
Page 12: ...2 4 Chapter 2 Hardware Installation...
Page 20: ...3 8 Chapter 3 Menu Tree Keyboard Functions and Quick Start...
Page 50: ...6 12 Chapter 6 Calibration...
Page 68: ...A 2 Appendix A Product Specifications...
Page 70: ...B 2 Appendix B Summary of Commands Used When Vessel Mounting Hot Keys...
Page 77: ...Appendix E E 1 This appendix not used at this time...
Page 78: ...Appendix E E 2...
Page 80: ...Appendix F Technical Drawings F 2...
Page 81: ...Appendix F Technical Drawings F 3...
Page 82: ...Appendix F Technical Drawings F 4...
Page 83: ...Appendix F Technical Drawings F 5...
Page 84: ...Appendix F Technical Drawings F 6...
Page 85: ...Appendix F Technical Drawings F 7...
Page 86: ...Appendix F Technical Drawings F 8...
Page 87: ...Appendix F Technical Drawings F 9...
Page 88: ...Appendix F Technical Drawings F 10...
Page 89: ...Appendix F Technical Drawings F 11...
Page 90: ...Appendix F Technical Drawings F 12...
Page 91: ...Appendix F Technical Drawings F 13...
Page 92: ...Appendix F Technical Drawings F 14...
Page 93: ...Appendix F Technical Drawings F 15...
Page 94: ...Appendix F Technical Drawings F 16...
Page 95: ...Appendix F Technical Drawings F 17...
Page 96: ...Appendix F Technical Drawings F 18...
Page 97: ...Appendix F Technical Drawings F 19...
Page 98: ...Appendix F Technical Drawings F 20...
Page 99: ...Appendix F Technical Drawings F 21...
Page 100: ...Appendix F Technical Drawings F 22...
Page 101: ...Appendix F Technical Drawings F 23...
Page 102: ...Appendix F Technical Drawings F 24...
Page 103: ...Appendix F Technical Drawings F 25...
Page 104: ...Appendix F Technical Drawings F 26...
Page 105: ...Appendix F Technical Drawings F 27...
Page 106: ...Appendix F Technical Drawings F 28...
Page 107: ...Appendix F Technical Drawings F 29...
Page 108: ...Appendix F Technical Drawings F 30...
Page 109: ...Appendix F Technical Drawings F 31...
Page 110: ...Appendix F Technical Drawings F 32...
Page 116: ...Appendix G Calculation of Maunal Calibration Parameters G 6...