Interface module safeties
The following Interface module-related Safety items are viewable and configurable in the Web
application.
Table 34: Interface Safety items
lower
warning
Safety
Item
Description
Hard limit
upper
Default
threshold
error
Maximum
Motor
Current
The measured motor
current in the connected
3rd party gripper (if
compatible gripper is
attached) is above the
higher limit. If gripper is
not present the safety is
disabled.
n/a
n/a
Maximum
Motor
Temperature
The motor temperature of
the connected 3rd party
gripper (if compatible
gripper is attached) is
above the higher limit. If
gripper is not present the
safety is disabled.
n/a
n/a
16.0 V
18.0 V
Minimum
Voltage
Voltage reading below
lower limit
Note:
minimum voltage
thresholds must be
below maximum voltage
thresholds
24.0 V
16.0 V
24.0 V
30.0
Maximum
Voltage
Voltage reading above
upper limit
Note:
maximum voltage
thresholds must be
above minimum voltage
thresholds
31.0 V
31.0
0.0 °C
80.0 °C
Maximum
Core
Temp
.
Core temperature above
upper limit
100.0 °C
90.0 °C
Non-
Volatile
Memory
Corrupted
Non-volatile memory
corrupt
n/a
n/a
Emergency
Line
Asserted
Emergency line asserted.
Motor drive disabled
n/a
n/a
Watchdog
Triggered
Watchdog triggered
n/a