84
lower
warning
Safety Item
Description
Hard
limit
upper
Default
threshold
error
0.0 °C
70.0 °C
Maximum
Ambient
Temperature
The ambient temperature is
above upper limit
90.0 °C
80.0 °C
0.0 °C
75.0 °C
Maximum
Core
Temperature
The core temperature is
above upper limit
100.0 °C
85.0 °C
Joint Fault
At least one joint is in a fault
state
n/a
n/a
Joint
Detection
Error
The number of detected
joints does not match the
configured arm joint count.
n/a
n/a
Network
Initialization
Error
Arm is detected but control
bus link is down
n/a
n/a
0.0 A
9.0 A
Maximum
Current
The base current reading is
above upper limit
12.0 A
10.0 A
16.0 V
18.0 V
Minimum
Voltage
The base voltage reading is
below lower limit
Note:
The minimum
voltage must be lower
than
the maximum
voltage
24.0 V
16.0 V
24.0 V
30.0 V
Maximum
Voltage
The base voltage reading is
above upper limit.
Note:
The maximum
voltage must be higher
than the minimum
voltage
31.0 V
31.0 V
Emergency
Stop Activated
Emergency stop activated.
Note:
electronic
protection cannot be
deactivated
n/a
n/a
Inrush Current
Limiter Fault
Inrush current limiter fault
triggered.
Note:
electronic
protection cannot be
deactivated
n/a
n/a
Firmware
Update Failure
Indicates a failure in the
firmware update process.
n/a
n/a
Base (controller) safeties
The following Base-related Safety items are viewable in the
Web App
.
Table 32: Base Safety items