Command Reference
Reflection Measurement Option Subsystem
144
Reflection Measurement Limit Type
:CALCulate:LLINe[1]|2:TYPE UPPer|LOWer
:CALCulate:LLINe[1]|2:TYPE?
This command toggles the limit type between upper limit
and lower limit.
Example:
:CALCulate:LLINe:TYPE UPPer
Key access:
Shift > Limit > Limit1 > Type
Reflection Measurement Limit Line State
:CALCulate:LLINe[1]|2:STATe OFF|ON|0|1
:CALCulate:LLINe[1]|2:STATe?
This command turns on/off the limit line in CAT test.
Example:
:CALCulate:LLINe:STATe ON
Key access:
Shift > Limit > Limit1 > Limit Line On/Off
Reflection Measurement Limit Line Value
:CALCulate:LLINe[1]|2:Y <value>
:CALCulate:LLINe[1]|2:Y?
This command defines the limit line value in reflection
measurement.
Example:
:CALCulate:LLINe:Y 15
Key access:
Shift > Limit > Limit1 > Limit Line On/Off
Reflection Measurement Limit State
:CALCulate:LLINe[1]|2:DISPlay OFF|ON|0|1
:CALCulate:LLINe[1]|2:DISPlay?
This command turns on/off the limit in reflection
measurement. This limit is different from the limit line
describe above, it is combined by several limit line with
different amplitudes and different frequency points.
Example:
:CALCulate:LLINe1:DISPlay 1
Key access:
Shift > Limit > Limit1 > Limit On/Off