Command Reference
Channel Scanner Option Subsystem
150
Measurement Interval State
:CHSCanner:SWEep:INTerval[:STATe] OFF|ON|0|1
:CHSCanner:SWEep:INTerval [:STATe]?
Use this command to turn on/off measurement interval
state.
Example:
:CHSCanner:SWEep:INTerval ON
Key access:
Meas > Setup > Meas Interval
Measurement Interval Time
:CHSCanner:SWEep:INTerval:TIME <value>
:CHSCanner:SWEep:INTerval:TIME?
Use this command to define the measurement interval time.
Range:
100 ms to 3600 s
Example:
:CHSCanner:SWEep:INTerval:TIME 10s
Key access:
Meas > Setup > Interval Type
Top N/Bottom N Measurement Rule
:CHSCanner:SWEep:TOPBottom:RULE:MEASure
SPEed|ACCUracy
:CHSCanner:SWEep:TOPBottom:RULE:MEASure?
Use this command to toggle the top/bottom N measurement
rule between speed and accuracy.
Example:
:CHSCanner:SWEep:TOPBottom:RULE:MEASure ACCUracy
Key access:
Meas > Setup > Measurement Rule
Top N/Bottom N Search Rule
:CHSCanner:SWEep:TOPBottom:RULE SPEed|ACCUracy
:CHSCanner:SWEep:TOPBottom:RULE?
This command toggles the top/bottom N measurement rule
between speed and accuracy. It’s only available for Top N
and Bottom N sweep mode.
Example:
:CHSCanner:SWEep:TOPBottom:RULE ACCUracy
Key access:
Meas > Setup > Search Rule