169
Command Reference
Demodulation Option Subsystem
AM Equal Low Pass Filter
[:SENSe]:AMA:EQLPfilter
AUTO|OFF|IFBW6|IFBW20|IFBW60|IFBW200|IFBW600|IFB
W2000
[:SENSe]:AMA:EQLPfilter?
Use this command to set the equal low pass filter in AM
demodulation analysis.
Range:
AUTO, OFF, IFBW6, IFBW20, IFBW60, IFBW200, IFBW600,
IFBW2000
Example:
:AMA:EQLPfilter IFBW6
Key access:
Meas > Equal LPF
AM Limit State
:CALCulate:AMA:LIMit OFF|ON|0|1
:CALCulate:AMA:LIMit?
Use this command to turn on/off the limit in AM
demodulation analysis.
Example:
:CALCulate:AMA:LIMit 1
Key access:
Shift > Limit> Limit On/Off
AM Carrier Power Upper Limit
:CALCulate:AMA:LIMit:POWer:UPPer <value>
:CALCulate:AMA:LIMit:POWer:UPPer?
Use this command to set the upper limit of AM carrier
power.
Range:
–100 to 30 dBm
Example:
:CALCulate:AMA:LIMit:POWer:UPPer -20
Key access:
Shift > Limit> CarrPwr Upper