117
Command Reference
Power Measurement Subsystem
SEM Channel Integrate Bandwidth
[:SENSe]:SEMask:BANDwidth|BWIDth:INTegration
<freq>
[:SENSe]:SEMask:BANDwidth|BWIDth:INTegration?
Use this command to specify reference channel integrate
bandwidth in SEM measurement.
Example:
:SEMask:BANDwidth:INTegration 2 MHz
Key access:
Meas > SEM > Ref Channel > Chan Integ BW
SEM Resolution Bandwidth
[:SENSe]:SEMask:BANDwidth|BWIDth <freq>
[:SENSe]:SEMask:BANDwidth|BWIDth?
Use this command to specify resolution bandwidth of
reference channel in SEM measurement.
[:SENSe]:SEMask:BANDwidth|BWIDth:AUTO OFF|ON|0|1
[:SENSe]:SEMask:BANDwidth|BWIDth:AUTO?
Automatically selects the resolution bandwidth to balance
the measurement accuracy and test speed.
Example:
:SENSe:SEMask:BANDwidth 30 Hz
Key access:
Meas > SEM > Ref Channel > Res BW
SEM Total Power Reference
[:SENSe]:SEMask:CARRier[:POWer] <value>
[:SENSe]:SEMask:CARRier[:POWer]?
Use this command to specify the total power reference in
SEM measurement. The unit of the amplitude is dBm.
[:SENSe]:SEMask:CARRier:AUTO[:STATe] OFF|ON|0|1
[:SENSe]:SEMask:CARRier:AUTO[:STATe]?
Automatically select the total power reference.
Example:
:SEMask:CARRier -40
Key access:
Meas > SEM > Ref Channel > Total Pwr Ref