Command Reference
Sense Subsystem
82
Trace Subsection
Select Trace Display Mode
:TRACe1|2|3|4:MODE WRITe|MAXHold|MIN-
Hold|VIEW|BLANk
:TRACe1|2|3|4:MODE?
Selects the display mode for the selected trace.
WRITe
puts the trace in the normal mode, updating the data.
MAXHold
displays the highest measured trace value for all
the data that has been measured since the function was
turned on.
MINHold
displays the lowest measured trace value for all the
data that has been measured since the function was turned
on.
VIEW
turns on the trace data so that it can be viewed on the
display.
BLANK
turns off the trace data so that it is not viewed on
the display.
Example:
:TRAC1:MODE VIEW
Key access:
Trace > Clear Write
|
Max Hold
|
Min Hold
|
View
|
Blank
Trace Max/Min Hold By Count
:TRACe[1]|2|3|4:HOLD:COUNt <value>
:TRACe[1]|2|3|4:HOLD:COUNt?
Use this command to set the Max/Min hold counter.
Example:
:TRACe:HOLD:COUNt 20
Key access:
Trace > More > Max/Min Number On
Add Trace
:TRACe:MATH:ADD
<destination_trace>,<source_trace1>,<source_trace2>
adds the selected trace on the activated trace.
Example:
:TRAC:MATH:ADD TRACE2,TRACE1,TRACE3