background image

 

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12914-00 / 4719

 

Operating 
instructions 

Cobra SMARTsense Chloride Ion 

 

 

12914-00 

 

PHYWE Systeme GmbH & Co. KG 
Robert-Bosch-Breite 10 
D

–37079 Göttingen 

 
Telefon 

+49 (0) 551 604–0 

Fax   

+49 (0) 551 604–107 

E-mail 

[email protected] 

Internet 

www.phywe.com 

 

 

 

The unit complies 
with the applicable 
EC-guidelines 
 

 

 

  

 

Fig. 1: 12914-00 Cobra SMARTsense Chloride  Ion 

TABLE OF CONTENTS 

1

 

SAFETY PRECAUTIONS

 

2

 

PURPOSE AND CHARACTERISTICS

 

3

 

FUNCTIONAL AND OPERATING ELEMENTS

 

4

 

NOTES ON OPERATION

 

 

HANDLING

 

6

 

TECHNICAL DATA

 

7

 

SCOPE OF DELIVERY

 

8

 

ACCESSORIES

 

9    CONFORMITY

 

10

 

DISPOSAL

 

 

1  SAFETY PRECAUTIONS 

 

 

Carefully  read  these  operating  instructions  completely 
before  operating  this  instrument.  This  is  necessary  to 
avoid damage to it, as well as for user-safety. 

 

Only use the instrument for the purpose for which it was 
designed. 

 

Only use the instrument in dry rooms in which there is no 
risk of explosion. 

 

Protect  the  instrument  from  dust, moisture and  vapours. 
Use a slightly moist lint-free cloth to clean the instrument. 
Do not use aggressive cleaning agents or solvents. 

2  PURPOSE AND CHARACTERISTICS 

The sensor is used for the measurement of chloride ion con-
centrations in liquids and the wireless transmission of the 
measured values via Bluetooth to any end device such as 
tablets, smartphones, etc. 

 

Caution! 

Summary of Contents for Cobra SMARTsense Chloride Ion

Page 1: ...IES 9 CONFORMITY 10 DISPOSAL 1 SAFETY PRECAUTIONS Carefully read these operating instructions completely before operating this instrument This is necessary to avoid damage to it as well as for user safety Only use the instrument for the purpose for which it was designed Only use the instrument in dry rooms in which there is no risk of explosion Protect the instrument from dust moisture and vapours...

Page 2: ... the on button for more than 3 seconds The Bluetooth LED lights up red Start the soft ware and select the sensor There is a 9 digit code on the back of the sensor Fig 2 The last 4 digits of the code corresponds to the last four digits of the sensor name in the soft ware Fig 3 Fig 2 This allows an exact assignment of the sen sors with the software Fig 3 After the sensor has been selected in the sof...

Page 3: ...under the golden metal nose Fig 7 1 Make sure that the battery is completely under the metal nose and completely pushed to the upper edge Push the battery into the socket by pressing lightly on the oppo site side The battery slips under the two plastic lugs Fig 7 2 which is also noticed by a short click Fig 7 Before closing make sure that the seal in the lid is not bent and lies neatly on the edge...

Page 4: ... returned to the local recycling sta tions PHYWE Systeme GmbH Co KG Abteilung Kundendienst Robert Bosch Breite 10 D 37079 Göttingen Telefon 49 0 551 604 274 Fax 49 0 551 604 246 Do not dispose of this product with normal household waste If this unit needs to be disposed of please return it to the address that is stated below for proper disposal ...

Reviews: