1-8
BOP HIPWR 080709
SAVE/RECALL CHARACTERISTICS
(See PAR. 3.3.8)
Number of Locations
99
Parameters Saved or Recalled
All parameters saved for power-up.
Mode of operation
Voltage, Current or External
For External the operating mode is deter-
mined by signal at I/O Port; no signal selects
voltage mode (see PAR. 3.4.2).
Reference type
Internal, External or
External Reference Level
Main channel
Internal, External or
Lesser Limit
Limit channel
Main Amplitude
(Internal)
0 to EO
NOM
or IO
NOM
(internal or external)
Main Channel:
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode
Protection Limit Amplitude
(Internal)
EO
MIN
or IO
MIN
to
1.01 EO
NOM
or IO
NOM
Limit Channel, Positive and Negative
Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode
Output status
ON or OFF
MISCELLANEOUS FEATURES
Maximum/Minimum Settings
Protection Limit
Type
Bipolar (default) or Independent
Main Channel
0 to EO
NOM
or IO
NOM
(default)
Software limit to setting of main channel
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode
Protection Limit Channel
(maximum value, Internal)
EO
MIN
or IO
MIN
to
1.01 EO
NOM
or IO
NOM
(internal)
Software limit to setting of protection limit
channel.
Voltage (Volts) for Current mode
Current (Amperes) for Voltage mode
Load Type Settings
Active (default), Resistive,
Battery, Custom
Consult factory for custom setting.
Self-test capabilities
Display, Keypad, Interface, Serial
Interface, Analog, Output
Serial Interface test requires Loop Back Test
connector (p/o KIT 219-0436, see Table 1-5).
Interface Settings
Data Format
SCPI (default), CIIL
GPIB Address
0 to 30 (6 = default)
Output Status @ Reset
ON or OFF (OFF = default)
Serial Baud Rate
Off, 9600, 19200 (Off = default)
Device Clear
SCPI (default) or MATE
XON/XOFF
Enable (default) or Disable
Prompt
Disable (default), Enable,
Enable with Echo
Calibration
Assisted by front-panel prompts
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
RATING/DESCRIPTION
Summary of Contents for BOP 1000W
Page 2: ......
Page 10: ......
Page 20: ......
Page 31: ......
Page 32: ......
Page 36: ......
Page 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 64: ......
Page 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Page 125: ......
Page 128: ......