BOP-1K 080709
B-7
B.14 OUTPut[:STATe]
QUERY
OUTP?
Syntax:
Short Form: OUTP[:STAT]?
Long Form: OUTPut[:STATe]?
Return Value: <int_value> (0 or 1)
Description:
Indicates whether power supply output is enabled or disabled.
Returns 0 if output disabled,
returns 1 if output enabled. Related Commands: OUTP.
B.15 OUTPut:MODE COMMAND
OUTP:MODE
Syntax:
Short Form: OUTP:MODE {ACTIVE | RESISTIVE | BATTERY}
Long Form: OUTPut:MODE {ACTIVE | RESISTIVE | BATTERY}
Description:
Determines how the unit functions when output is turned off depending on the type of load in
use: active, resistive or battery.
See PAR. 3.3.6 for description of ACTIVE, RESISTIVE and BAT-
TERY modes.
B.16 OUTPut:MODE?
QUERY
OUTP:MODE?
Syntax:
Short Form: OUTP:MODE?
Long Form: OUTPut:MODE]?
Return Value: ACTIVE | RESISTIVE | BATTERY
Description:
Indicates whether power supply is configured for ACTIVE, RESISTIVE or BATTERY type loads.
See PAR. 3.3.6 for description of ACTIVE, RESISTIVE and BATTERY modes. Related Commands:
OUTP:MODE.
B.17 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] COMMAND
CURR
Syntax:
Short Form: [SOUR:]CURR[:LEV][:IMM][:AMP] <exp_value>
Long Form: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1
Description:
Sets programmed current level at power supply output.
This command programs output current to
a specific value; actual output current will depend on load conditions. Any data that exceeds I
MAX
causes error message -222 “data out range” to be posted to the error queue (See example, Figure B-
1.)
B.18 [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude] QUERY
CURR?
Syntax:
Short Form: [SOUR:]CURR[:LEV][:IMM][:AMP]? MIN, MAX
Long Form: [SOURce:]CURRent[:LEVel][:IMMediate][:AMPlitude]? MIN, MAX
Return Value:
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1
Description:
Returns either the programmed value, maximum value, or minimum value of current.
The
CURR? query returns the programmed value of current. Actual output current will depend on load con-
ditions. The CURR?MAX query returns the maximum positive current allowed for a particular model.
CURR? MIN returns minimum negative current allowed for power supply (always negative).
Related
Commands:
CURR. (See example, Figure B-1.)
B.19 [SOURce:]CURRent[:LEVel]:LIMit[:BOTH] COMMAND
CURR:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]CURR[:LEV]:LIM[:BOTH] <value>
Long Form: [SOURce:]CURRent[:LEVel]:LIMit[:BOTH] <value>
where <value> is between zero and I
NOM
Description: Establishes the software limit <value> for output current, i.e., sets the maximum value of output cur-
rent that the unit will be allowed to source and sink. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations. (See Figure B-
4)
B.20 [SOURce:]CURRent[:LEVel]:LIMit[:BOTH]? QUERY
CURR:LIM[:BOTH]?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]CURRent[:LEVel]:LIMit[:BOTH]?
Returns <value>, <value>
Description: Identifies the positive software limit, followed by the negative software limit value of output current that
the unit can source or sink.
Summary of Contents for BOP 1000W
Page 2: ......
Page 10: ......
Page 20: ......
Page 31: ......
Page 32: ......
Page 36: ......
Page 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 64: ......
Page 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Page 125: ......
Page 128: ......