3-13
3.3.3.1
SELECTING BIPOLAR/INDEPENDENT PROTECTION LIMITS
The BOP can be configured to show the protection limits as either a single value that applies to
both protection channels or show individual settings for positive and negative protection limits.
Selecting Independent protection limits means that the positive and negative limits are dis-
played (and can be modified) independently. Bipolar means that for each protection limit (volt-
age or current) a single value applies to both the positive and negative limits; only one value is
displayed and can be edited for both ± protection limits.
TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS
Term
Definition
To modify
refer to PAR.
Local
Remote
+E
Onom
–E
Onom
The nominal (rated) output voltage of the unit determined by model; e.g. for
a BOP 36-28MG, ±E
Onom
is 36V.
N/A
N/A
+I
Onom
–I
Onom
The nominal (rated) output current of the unit determined by model; e.g. for
a BOP 36-28MG, ±I
Onom
is 28A.
N/A
N/A
+Voltage
–Voltage
Voltage mode only.
Positive (+) and negative (–) output voltage values
established by keypad or remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min
3.3.3
B.84
+Voltage max
–Voltage min
Voltage mode only.
Maximum (positive) and minimum (maximum negative)
voltage that can be set.
Value (+): 0 to +E
Onom
Value (–): 0 to –E
Onom
3.3.4.1
B.86, B.87,
B.88, B.90
+Current Protect
–Current Protect
Voltage mode only.
Defines maximum (+) current and Minimum (maximum
negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min
3.3.3
B.27, B.28,
B.33, B.31
+Current Protect Max
–Current Protect Min
Voltage mode only.
Maximum setting for +Current Protect and Minimum
(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)
3.3.4.2
B.35, B.36,
B.39, B.37
Minimum (box)
+Current Protect Min
–Current Protect Max
Voltage mode only.
Minimum (positive) setting for +Current Protect and
maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
rent Protect bCurrent Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the
minimum (box)
is
automatically calculated by the BOP (see Figure 1-3).
N/A
N/A
+Voltage Protect
–Voltage Protect
Current mode only.
Maximum positive (+) and minimum (maximum
negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min
3.3.3
B.94, B.95,
B.100,
B.98
+Voltage Protect Max
–Voltage Protect Min
Current mode only.
Maximum (positive) setting for +Voltage Protect and
Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)
3.3.4.2
B.102,
B.103,
B.106,
B.104
Summary of Contents for BOP 1000W
Page 2: ......
Page 10: ......
Page 20: ......
Page 31: ......
Page 32: ......
Page 36: ......
Page 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 64: ......
Page 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Page 125: ......
Page 128: ......