4-4
BOP-1K 080709
4.3
CALIBRATION USING REMOTE SCPI COMMANDS VIA GPIB OR RS 232 INTERFACE
The primary means of adjustment are the
CAL:DATA
commands. Basically these commands
are fine and coarse adjustments, however there are slight differences in how they work for dif-
ferent types of calibrations.
a.
ZERO Calibrations (always done first).
The only means of adjustment is the
CAL:DATA <VALUE>
command which provides a total of 4095 increments of adjustment start-
ing at 0, with 2047 increments in either direction to achieve maximum output levels of ±2.5% of
E
Onom
. Adjust the output to obtain the closest value to zero.
b.
MAX and MIN Calibrations.
The primary means of adjustment is the
CAL:DATA <VALUE>
command to either increase (
CAL:DATA 1
) or decrease (
CAL:DATA -1
) the output value.
Adjustment can be done in larger increments by increasing the numeric value, e.g.,
CAL:DATA +10
or
CAL:DATA -10
. Adjust the output to obtain the closest value above the full
scale value.
c.
VPR and CPR Calibrations.
The only means of adjustment is the
CAL:DATA <VALUE>
command which provides a total of 4095 increments of adjustment from zero to maximum.
Adjust the output to obtain the closest value above the full scale value.
TABLE 4-3. VOLTAGE CALIBRATION MEASUREMENTS AND TOLERANCES
MODEL
VOLTAGE
ZERO
±FULL SCALE
VOLTAGE
±FULL SCALE
VPR LIMIT
BOP 10-75MG
0V
±0.0001V
10V (MAX
)
-10V (MIN
)
±0.001V
10V (MAX
)
-10V (MIN
)
±0.003V
BOP 20-50MG
0V
±0.0002V
20V (MAX
)
-20V (MIN
)
±0.002V
20V (MAX
)
-20V (MIN
)
±0.006V
BOP 36-28MG
0V
±0.0036V
36V (MAX
)
-36V (MIN
)
±0.0036V
36V (MAX
)
-36V (MIN
)
±0.01V
BOP 50-20MG
0V
±0.005V
50V (MAX
)
-50V (MIN
)
±0.005V
50V (MAX
)
-50V (MIN
)
±0.015V
BOP 72-14MG
0V
±0.0072V
72V (MAX
)
-72V (MIN
)
±0.0072V
72V (MAX
)
-72V (MIN
)
±0.022V
BOP 100-10MG
0V
±0.01V
100V (MAX
)
-100V (MIN
)
±0.01V
100V (MAX
)
-100V (MIN
)
±0.03V
Summary of Contents for BOP 1000W
Page 2: ......
Page 10: ......
Page 20: ......
Page 31: ......
Page 32: ......
Page 36: ......
Page 50: ...FIGURE 2 2 LOAD CONNECTIONS LOCAL SENSING...
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 64: ......
Page 68: ...FIGURE 3 3 POWER UP SCREEN SHOWING GRAPHIC METERS VOLTAGE 0000 0...
Page 125: ......
Page 128: ......