27
Factory Defaults
To reset the PRO SOLO Mk3 to its factory default settings, hold down all three buttons whilst
turning on the power. The display will show “Fd” to show that it has been done.
From the factory or following the above reset procedure, programs 1 to 26 are all loaded with
the default setup for use with a Roland SH-101. This setup is also suitable for a lot of other
standard CV / Gate synthesizers, including the majority of modern equipment.
The following programs for other synthesizers are loaded into the following locations:
Prog
Synthesizer
Changes from default setup
#32
Roland SH-09 (also Moog Prodigy Mk1 w/ Kenton skts) Gate 15V
#31
Minimoog (original model)
S-trig, coarse tune -5 semitones
#30
Other Moog
S-trig, coarse tune zero
#29
Korg MS-10 & MS-20
S-trig, Hz/V
#28
Yamaha CS-10
S-trig with 5V pullup, Hz/V
#27
ARP 2600 (also Odyssey Mk1 w/ Kenton skts)
Gate 15V, Aux 1 set to Note Trig
Note:
A comprehensive list of what settings to use with which synthesizer, as well as the required leads
and any other instrument-specific notes can be found on our website at:
www.kenton.co.uk/synthselector