25
Parameter List
–
ADSR Envelope Generator (contd.)
P86
EG Attack Time CC
(default: 20)
Range: 0 to 119
Sets which CC will control the ADSR attack time.
P87
EG Decay Time CC
(default: 21)
Range: 0 to 119
Sets which CC will control the ADSR decay time.
P88
EG Sustain Level CC
(default: 22)
Range: 0 to 119
Sets which CC will control the ADSR sustain level.
P89
EG Release Time CC
(default: 23)
Range: 0 to 119
Sets which CC will control the ADSR release time.
Parameter List
–
Other
P90
Socket Select
(default: MIDI Thru)
[MO]
MIDI Thru (and Out for SysEx program dump)
[S24]
Sync 24 (fixed at 24 CPQN)
[CL1]
Sync 24 (using Clock Divider 1)
[CL2]
Sync 24 (using Clock Divider 2)
Sets the function of the MIDI Thru / Sync 24 socket.
P91
SysEx Device Number
(default: 1)
Range: 1 to 16
Sets the MIDI SysEx device number for this unit.
P92
Continue = Start
(default: On)
Range: Off or On
Sets how MIDI Continue messages are treated. When turned on, these messages are treated as if they
were MIDI Start messages. When turned off, Continue messages will only be treated
as Start if
immediately preceded by a Song Position Pointer = 0 message. (Some sequencers use this instead of a
start message)
Note: This parameter affects the Sync 24 output as well as the Clock Start / Stop Aux Controller.