MRG
MRG
MRG
MRG----1
1
1
1
0
0
0
0
Configuration method
Configuration method
Configuration method
Configuration method
4-9
[5-5] Bottom Window
Parameter
Default Value
Description
0-0.5
0.3
Parameter range in metric [m] units
If measurement unit is [ft], display will be converted to show ‘feet’ units.
Valid only when [5-7] is set at “0".
[5-6] First Echo Flag
Parameter
Value
Description
0
Max Echo
Max strength echo defined as surface echo
1
First Echo
First echo defined as surface echo
[5-7] Bottom Visible
Parameter
Value
Description
0
Bottom Visible
When tank bottom echo is larger than surface echo
(such as with oil fluids). Effective against echo
misdetection.
1
Bottom Invisible
When tank bottom echo is smaller that surface echo
(such as with water). Setting “1”, invalidates this
function.
Measurement Range (R)
Peak detectable range
Bottom window
Surface echo
Bottom echo
Distance
Detected as Surface echo
at First Echo setting
Detected as Surface echo
at Max Echo setting
S
ig
n
a
l A
m
p
lit
u
d
e