Mechanical Installation
Mechanical Installation
Mechanical Installation
Mechanical Installation
2-7
Transmitter
Union Nut
Set Screw
O-ring
Sleeve
Antenna
Adapter
!!!!
Warning
Make sure that the O-ring inside of the sleeve is clean as
improper sealing may lead to gas leakage problems
when the MRG-10 is installed on pressurized tanks.
3. Carefully insert the antenna adapter of the transmitter into the sleeve.
Secure the antenna adapter with the union nut.
Make sure that the antenna adapter fits inside
of the cone antenna.
Secure the union nut with the set screw.
4. Place the gasket on the tank nozzle.
Carefully fit the flange and the cone antenna
on the tank nozzle.
Tighten the assembly with the screws and nuts.
!!!!
Warning
Do not loosen the union nut when the tank is pressurized.
Gasket
Tank
Nozzle