Operating and appliance data
© KEB, 2008-02
COMBIVERT R6-S
Page 3.2 - 7
3
10
Parameter
Addr.
R PG E Min. value
Max. value Res.
[?]
Default
ru.20
DC output voltage / peak
value
0214h rw
-
-
0
778
1
V
-
Parameter ru.20 enables to recognize voltage peaks within an operating cycle. For that the highest value
of ru.19 is stored in ru.20. The peak value memory can be cleared by pressing the UP, or DOWN key or via
bus by writing any value you like to the address of ru.20. Switching off COMBIVERT R6-S also clears the
memory.
Parameter
Addr.
R PG E Min. value
Max. value
Res. [?] Default
ru.21 Input terminal state
0215h
ro
-
-
0
4095
1
-
-
Display of the digital inputs set currently. The logic levels are indicated at the input terminals or at the inter-
nal inputs regardless of the following logic operations (see chapter 3.3 „Digital inputs“). According to follow-
ing table a specific decimal value is given out for each
digital input. If several inputs are controlled, the sum
of the decimal values is indicated.
Bit
Decimal value Input
Terminal
0
1
ST (prog. input „control release/reset“)
X2A.12
1
2
RST (prog. input „reset“)
no
2
4
F (prog. input)
no
3
8
R (prog. input)
no
4
16
I1 (prog. input 1)
X2A.13
5
32
I2 prog. input 2)
X2A.14
6
64
I3 (prog. input 3)
X2A.15
7
128
I4 (prog. input 4)
X2A.16
8
256
IA (internal input A)
no
9
512
IB (internal input B)
no
10
1024
IC (internal input C)
no
11
2048
ID (internal input D)
no
Parameter
Addr.
R PG E Min. value
Max. value Res.
[?]
Default
ru.22
Internal input state
0216h ro
-
-
0
4095
1
-
-
Display of the digital external and internal inputs set currently. The input is only regarded as set if it is available
as effective signal to the further processing (i.e. accepted through strobe, edge-triggering or logic operation).
According to table like
ru.21 a specific decimal value is
output for each digital input. If several inputs are con-
trolled, the sum of the decimal values (see ru.21) is indicated (also see chapt. 3.4 „Digital inputs“).
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......