Define CP-Parameters
3.9.2 Assignment of the CP-Parameters
CP selector (ud.15)
The CP-Parameter to be programmed in a range of 1...36 is adjusted with ud.15. CP.00 is not adjustable.
CP address (ud.16)
ud.16 determines the parameter address of the parameter to be displayed:
ud.16:
CP address
Not available or not allowed pa-
rameter addresses are rejected
with "data invalid".
-1:
Parameter not used
0...32767:
Parameter address
CP Set norm (ud.17)
The set, the addressing and the norm of the parameter to be displayed are specified with ud
.17. The parameter
is bit-coded. The individual bits are decoded as follows:
Define set selection for direct set addressing
Bit 0...7 determine the set selection for direct set programming i.e., all selected sets gets the same value, deter-
mined by the CP-Parameter. If direct set programming (bit 8, 9) is selected, at least one set must be selected,
otherwise error message "set invalid" is displayed in the CP menue.
Bit
7
6
5
4
3
2
1
0
Value
Set
0
0
0
0
0
0
0
0
0
no
-> Data invalid, if bit 8 + 9 = 0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
1
0
2
1
0
0
0
0
0
1
0
0
3
0+1
...
...
...
1
1
1
1
1
1
1
1
255
All
Define set addressing mode
Bit
8 and 9 determine the set addressing mode:
Bit
8
9
Value Function
0
0
0
direct set addressing; the defined sets of bit 7 .. 0 are valid
0
1
256 actual set; the actual set is displayed / edited
1
0
512 indirect set addressing, the parameter set determined by the set pointer Fr.09
is displayed / edited
1
1
768 reserved
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......