Define CP-Parameters
© KEB, 2008-02
COMBIVERT R6-S
Page 3.9 - 5
3
10
Display standardization
Bit 10 .. 12 determines how to display the parameter value. With parameters ud.18 ... 21 it
is possible to define
up to seven different user standardizations (below in this chapter).
Bit
12
11
10 Value Function
0
0
0
0
Use standardization of the parameter
0
0
1
1024 Display standardization of parameters ud.18...21 of set 1
0
1
0
2048 Display standardization of parameters ud.18...21 of set 2
...
...
1
1
1
7168 Display standardization of parameters ud.18...21 of set 7